Cga580 vs Post Cornelius PIN: specs compared

Updated 05 September 2026.

5
specs differ

Cga580 and Post Cornelius PIN differ on 5 specs: designation, size / thread, fitting form, seals on, rating / role.

SpecCga580Post Cornelius PIN
Designation0.965"-14 NGO RH19/32"-18 UNF (both posts)
Size / thread0.965"-14 NGO (National Gas Outlet), right hand, external19/32"-18 UNF (about 15.1 mm major), gas and liquid the same
Fitting formcylinder valve outlet nut, externalUNF male post thread
Seals onnylon or fibre washer inside the nut against the valve outletpoppet inside the post; post base O-ring seals to the keg lid
Rating / rolethe North American connection for nitrogen, argon and beer-gas (N2/CO2 mix) cylinders, up to 3000 psigCornelius pin-lock corny kegs; the disconnect locates on pins, not the thread

Questions and answers

How do Cga580 and Post Cornelius PIN compare?

Cga580 and Post Cornelius PIN differ on 5 specs: designation, size / thread, fitting form, seals on, rating / role.

Compared here

CGA-580 nitrogen / beer-gas cylinder valve (0.965"-14 NGO RH)Cornelius pin-lock keg post (19/32"-18 UNF (both posts))